NTRODUCTION
UDISAT 450 is a fully automatic, random access analyzer designed to support the modern laboratory in achieving improved cost efficiency, reduced rerun and manual handling. It provides quality results while following rigid quality system procedures and in strict compliance with regulatory agency requirements. |
|
|
SYSTEM DESCRIPTION
Fully Automatic, random access, continuous loading, benchtop open analyzer for Clinical Chemistry and Immunoturbidimetric assays
ASSAY TYPES
- End point, Kinetic, Differential, Fixed time, Bichromatic and Immunoturbidimetric
- up to 999 tests, all user programmable
REAGENTS ON BOARD
Up to 72 reagents can be located into the refrigerated compartment and distribuited on:
- 4 removable racks
- 50/20/5 ml containers can be loaded
- 8 extra positions for 5 ml containers
SAMPLE LOADING
- 4 universal, separate racks for continuos loading of samples, calibrators and controls
- each rack contains up to 15 cups and/or tubes 10-16 mm diam., 40-100 mm height
- 8 extra position for STAT samples, calibrators and controls
- STAT sample execution is allowed at any time
THROUGHPUT
Up to 450 tests/hour including I.S.E.
(300 tests/hour photometric)
READING SYSTEM
- direct reading, dual channel photometer
- 200 μl minimum reading volume
- 9 narrow band, automatically selected interferential filters 340, 380, 405, 492, 510, 546, 577, 620, 690
- halogen lamp 6V/10W
- linear from 0.0001 to 4.200 Abs.
- high resolution (0.0001 Abs.)
SAMPLING PROCESS
One mechanical arm performs all sampling operations with:
- liquid level sensing (capacitive)
- reagent pre-warming at 37° C
- automatic probe washing
- sample volume range: 2.0 μl ÷ 99 μl (0.25 μl incr.)
- reagent 1 volume range: 2.0 μl ÷ 348 μl (1 μl incr.)
- reagent 2 volume range: 2.0 μl ÷ 330 μl (1 μl incr.)
- reagent 3 volume range: 2.0 μl ÷ 330 μl (1 μl incr.)
- sample pre-dilution
- sample post-dilution
- sample post-concentration
REACTION PLATE
Holds 80 cuvettes divide into 4 racks with 20 cuvettes each and performs the following operations:
- automatic cuvette washing
- continuous monitoring of cuvette quality
- incubation temperature control at 37° C ± 0.3
COMPUTER (OPTIONAL) MINIMUM REQUIREMENTS
- CPU: Intel or AMD
- MEMORY: Ram 2 Gbyte
- HARD DISK: 250 Gbyte
- MONITOR: 17“
- COMMUNICATION: USB and/or RS232 port
- HOST COMMUNICATION: RS232 or Ethernet
- OPERATIVE SYSTEM: WINDOWS XP - VISTA - 7 (32 bit only)
OPTIONS
- Direct potentiometry I.S.E. module for Na+, K+, CI- (140 tests/hour)
- Positive barcode readers for reagents and samples (code 128, codebar, code 2 of 5 interleaved, code 39)
INSTALLATION REQUIREMENTS
- Power Supply: 90 ÷ 250 VAC, 47 ÷ 63 Hz
- Electric consumption: 386 Watt
- Water Consumption: 1.5 l/h
DIMENSIONS, WEIGHT & ENVIRONMENT
- Analytical Module:
- Height: 50 cm
- Width: 68 cm
- Lenght: 105 cm
- Weight: 49 Kg
- Room Temperature: 18° C ÷ 30° C
- Relative Humidity: 20% ÷ 85% |